Comparație de produse

Performance Data Temperature

Average cooling down time according to IEC 60068-3-5 [K/min] 4.2
Average heating-up rate according to IEC 60068-3-5 [K/min] 5.5
Max. heat compensation at 25 °C [W] 1500
Temperature fluctuation depending on setpoint [± K] 0.1 - 0.1
Temperature range [°C] -70 - 180
Temperature variation depending on setpoint [± K] 0.1 - 1.3

Electrical Data

Nominal power [kW] 5.0
Phase (Nominal voltage) 3~
Power frequency [Hz] 50
Rated Voltage [V] 400
Unit fuse [A] 16

Doors

Unit doors 1

Housing Dimensions (not incl. fittings and connections)

Depth net [mm] 865
Height net [mm] 1725
Width net [mm] 980

Internal Dimensions

Depth [mm] 400
Height [mm] 480
Width [mm] 600

Measures

Interior volume [L] 115
Load per rack [kg] 30
Net weight of the unit (empty) [kg] 330
Permitted load [kg] 60
Viewing window height [mm] 222
Viewing window width [mm] 288
Wall clearance back [mm] 300
Wall clearance sidewise [mm] 200

Environment-specific Data

Sound-pressure level [dB(A)] 64

Fixtures

Number of shelves (std./max.) 1/4

Performance Data Climate

Dew point temperature range [°C] 5 - 94
Humidity fluctuation depending on setpoint ≤2,5 ± % RH
Humidity range [% RH] 10 - 98
Temperature fluctuation depending on setpoint [± K] 0.1 - 1
Temperature range [°C] 10 - 95